- Home
- Search Results
- Page 1 of 1
Search for: All records
-
Total Resources1
- Resource Type
-
0000000001000000
- More
- Availability
-
10
- Author / Contributor
- Filter by Author / Creator
-
-
BRÁS, LISANDRA DE (1)
-
DIMBATH, ELIZABETH (1)
-
GEORGE, STEPHANIE (1)
-
VADATI, ALEX (1)
-
#Tyler Phillips, Kenneth E. (0)
-
#Willis, Ciara (0)
-
& Abreu-Ramos, E. D. (0)
-
& Abramson, C. I. (0)
-
& Abreu-Ramos, E. D. (0)
-
& Adams, S.G. (0)
-
& Ahmed, K. (0)
-
& Ahmed, Khadija. (0)
-
& Aina, D.K. Jr. (0)
-
& Akcil-Okan, O. (0)
-
& Akuom, D. (0)
-
& Aleven, V. (0)
-
& Andrews-Larson, C. (0)
-
& Archibald, J. (0)
-
& Arnett, N. (0)
-
& Arya, G. (0)
-
- Filter by Editor
-
-
& Spizer, S. M. (0)
-
& . Spizer, S. (0)
-
& Ahn, J. (0)
-
& Bateiha, S. (0)
-
& Bosch, N. (0)
-
& Brennan K. (0)
-
& Brennan, K. (0)
-
& Chen, B. (0)
-
& Chen, Bodong (0)
-
& Drown, S. (0)
-
& Ferretti, F. (0)
-
& Higgins, A. (0)
-
& J. Peters (0)
-
& Kali, Y. (0)
-
& Ruiz-Arias, P.M. (0)
-
& S. Spitzer (0)
-
& Sahin. I. (0)
-
& Spitzer, S. (0)
-
& Spitzer, S.M. (0)
-
(submitted - in Review for IEEE ICASSP-2024) (0)
-
-
Have feedback or suggestions for a way to improve these results?
!
Note: When clicking on a Digital Object Identifier (DOI) number, you will be taken to an external site maintained by the publisher.
Some full text articles may not yet be available without a charge during the embargo (administrative interval).
What is a DOI Number?
Some links on this page may take you to non-federal websites. Their policies may differ from this site.
-
Current literature reports a wide range of stiffness values and constitutive models for lung tissue across different spatial scales. Comparing the reported lung tissue stiffness values across different spatial scales may provide insights into how well those mechanical properties and the proposed constitutive models represent lung tissue’s mechanical behavior. Thus, this study applies in silico modeling to compare and potentially bridge the differences reported in lung tissue mechanical properties at different length scales. Specifically, we predicted the mesoscale mechanical behavior of rat lung tissue based on in situ and in vitro microscale test data using finite element (FE) analysis and compared those computational predictions to the reported data using mesoscale uniaxial experiments. Our simulations showed that microscale-based stiffness values differed from the mesoscale data in the simulated strain range of 0–60%, with the atomic force microscopy (AFM)-based data overestimating the mesoscale data above 15% strain. This research demonstrates that computational modeling can be used as an informative and guiding tool to investigate and potentially bridge the differences in reported lung tissue material properties across length scales.more » « less
An official website of the United States government
